← Public RFP analyses

Skinner Survey Building Roof Replacement

Source scope cues include: Asbestos was detected only in the roof penetration mastic of the Survey Building.; located at 1010 N Central Ave in Glendale, CA.; sticking the tape to a clear microscope (tape lift sampling).; Roof penetration mastic on the Survey Building was identified to be asbestos-containing.; Ensure the sources of water intrusion have been identified and repaired.; ‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data.; Water Treatment Plant.

BID WITH CAUTION 2 red flags detected : Federal Funding Compliance (ARPA / CDBG / HUD / FEMA / 2 CFR 200)

Free RFP preview

The quick read before you decide to bid

Bid/no-bid recommendation

BID WITH CAUTION

Scope summary

Source scope cues include: Asbestos was detected only in the roof penetration mastic of the Survey Building.; located at 1010 N Central Ave in Glendale, CA.; sticking the tape to a clear microscope (tape lift sampling).; Roof penetration mastic on the Survey Building was identified to be asbestos-containing.; Ensure the sources of water intrusion have been identified and repaired.; ‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data.; Water Treatment Plant.

Submission deadline

2020-03-18

Red flag teaser

2 red flags detected including Federal Funding Compliance (ARPA / CDBG / HUD / FEMA / 2 CFR 200).

Locked analysis

Full red flag list with excerpts

2 found

Federal Funding Compliance (ARPA / CDBG / HUD / FEMA / 2 CFR 200)

high

…0.5%) or greater is considered positive for LBP, in accordance with Chapter 7 (1997 revision) of the Housing and Urban Development (HUD) Guidelines for Lead Based Paint Inspection. If the result of greater than 600 ppm, but less than 5,000 ppm, it was considered lead-containing paint (LCP). The sample results are summarized in the following table. Table 1. Summary of Lead Results Sample Lead Resu

Hazardous Material / Abatement Coordination

high

April 2, 2020 Kushan Kuru Metropolitan Water District of Southern California 700 N. Alameda Street Los Angeles, CA90012 Re: Asbestos, Lead and Mold Sampling – Skinner Water Treatment Plant Roof Replacement at Survey & Dry Polymer Buildings Dear Mr. Kuru, This report documents the findings from an assessment conducted by Aurora Industrial Hygiene (Aurora) at the Skinneer Water Treatment Plant locat

Locked analysis

All deadlines table

1 dates
ItemDue
Lab ID-Version: 11331411-1, Analysis 2020-03-18

Locked analysis

Required certifications checklist

1 items
  • Include safety documents if required

Locked workspace

Guest view link to the interactive analysis

Open the full workspace to review evidence, generate response documents, and work from the analyzed checklist.

Analyzing your own RFP?

Email any RFP PDF to rfp@mail.bidterms.com and get a full analysis back in under 5 minutes, free.

Or start your free trial →

Related public analyses

More RFPs in a similar lane

View all